INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
www.continentalplaces.com • [email protected]
CERTIFIED UNDER AMERICAN NATIONAL STANDARDS, ANSI Z21.11.2, VOLUME II FOR UNVENTED ROOM HEATERS.
UNVENTED MILLIVOLT SYSTEM
INSTALLATION AND OPERATION INSTRUCTIONS FOR
UNVENTED GAS FIREPLACE
NATURAL GAS MODEL
CVF36N
PROPANE GAS MODEL
CVF36P
CERTIFIED FOR UNITED STATES USING ANSI METHODS
WARNING: If the information in these instructions is not followed exactly, a fi re or
explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapours and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from
a neighbour’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier,
call the fi re department.
Installation and service must be performed
by a qualifi ed installer, service agency or
the gas supplier.
This is an unvented gas-fi red heater that uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
$10.00
Vedere la pagina 0
1 2 3 4 5 6 ... 17 18

Sommario

Pagina 1 - UNVENTED MILLIVOLT SYSTEM

1W415-0298 / K / 12.06.07INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON

Pagina 2 - TABLE OF CONTENTS

10W415-0298 / K / 12.06.07FIGURE 22FIGURE 20Attach the connectors from the black and red wires to the blower. Attach and secure the variable speed swi

Pagina 3

11W415-0298 / K / 12.06.07When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed.1. STOP! Read th

Pagina 4 - LEAD TO DEATH

12W415-0298 / K / 12.06.07This procedure must be performed by a qualified service person!Inspect the pilot for any visible contamination or debris (us

Pagina 5 - INSTALLATION

13W415-0298 / K / 12.06.07Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered

Pagina 6 - OPTIONAL WALL SWITCH

14W415-0298 / K / 12.06.07

Pagina 7 - NAILING TAB INSTALLATION

15W415-0298 / K / 12.06.07Main burner goes out; pilot stays on.Pilot fl ame is not large enough or not engulfi ng the thermo-pile- service or replace O

Pagina 8 - FINISHING

16W415-0298 / K / 12.06.07Flames are consist-ently too large or too small. Carbon-ing occurs.- check pressure readings:Inlet pressure can be checked

Pagina 9 - OPTIONAL BLOWER INSTALLATION

17W415-0298 / K / 12.06.07Wolf Steel Fireplace Service HistoryThis fi replace must be serviced annually depending on usage.Date Service Technician Name

Pagina 10 - GD36 THERMOSTATIC SENSOR

18W415-0298 / K / 12.06.07NO TES

Pagina 11 - OPERATION / MAINTENANCE

2W415-0298 / K / 12.06.07PG 3-4 INTRODUCTION Warranty General Instructions General Information Care of Glass Door, Catalytic Tiles &

Pagina 12 - VENTURI ADJUSTMENT

3W415-0298 / K / 12.06.07CONTINENTAL® gas fireplaces are manufactured under the strict Standard of the world recognizedISO 9001:2000 Quality Assurance

Pagina 13 - REPLACEMENTS

4W415-0298 / K / 12.06.07Use only accessories designed for and listed with your specifi c fi replace.Early signs of carbon monoxide poisoning resem-ble

Pagina 14 - W415-0298 / K / 12.06.07

5W415-0298 / K / 12.06.07ROOM 2ROOM 1This heater shall not be installed in a confined space or unusually tight construction unless provisions are prov

Pagina 15 - TROUBLE SHOOTING GUIDE

6W415-0298 / K / 12.06.07Proceed once the vent installation is complete.NOTE: All gas connections must be contained within the fi replace when complet

Pagina 16 - SYMPTOM PROBLEM TEST SOLUTION

7W415-0298 / K / 12.06.07To install the fireplace face flush with the finished wall, position the framework to ac-commodate the thickness of the fi nis

Pagina 17 - Date Service Technician

8W415-0298 / K / 12.06.07The curtain mesh must be kept fully closed during operation to help prevent accidental burns from occurring. The heater must

Pagina 18

9W415-0298 / K / 12.06.07ACBFIGURE14HOODAttach the hood by pressing the top fl ange into the clips along the top of the louvre opening. Secure using a